All rights reserved. Publications of the World Health Organization can be obtained from WHO Press, World Health Organization, 20 Avenue Appia, 1211 Geneva 27, Switzerland (tel.: +41 22 791 3264; fax: +41 22 791 4857; e-mail: tni.ohw@sredrokoob). Requests for permission to reproduce or translate WHO publications — whether for sale or for noncommercial distribution — should be addressed to WHO Press, at the above address (fax: +41 22 791 4806; e-mail: tni.ohw@snoissimrep).
NCBI Bookshelf. A service of the National Library of Medicine, National Institutes of Health.
Atkinson J, Chartier Y, Pessoa-Silva CL, et al., editors. Natural Ventilation for Infection Control in Health-Care Settings. Geneva: World Health Organization; 2009.
- AIA. Guidelines for design and construction of hospitals and health care facilities. Washington: The American Institute of Architects Academy of Architecture for Health; 2001.
- Aintablian N, Walpita P, Sawyer MH. Detection of Bordetella pertussis and respiratory synctial virus in air samples from hospital rooms. Infection Control and Hospital Epidemiology. 1998;19(12):918–923. [PubMed: 9872529]
- Allard F, editor. Natural ventilation in buildings — a design handbook. London: James & James; 1998.
- Anderson JD, et al. Lack of nosocomial spread of Varicella in a pediatric hospital with negative pressure ventilated patient rooms. Infection Control. 1985;6(3):120–121. [PubMed: 3845064]
- Artenstein MS, et al. Large-volume air sampling of human respiratory disease pathogens. American Journal of Epidemiology. 1967;85(3):479–485. [PubMed: 4960866]
- ASHRAE. Handbook of HVAC applications. Atlanta, USA: American Society of Heating Refrigerating and Air-Conditioning Engineers Inc.; 2007. Health care facilities.
- ASHRAE. HVAC design manual for hospitals and clinics. Atlanta, USA: American Society of Heating Refrigerating and Air-Conditioning Engineers Inc.; 2007.
- ASHRAE. ASHRAE handbook fundamentals. Atlanta, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc.; 2009.
- Awbi HB. Ventilation of buildings. 2nd ed. New York: Taylor & Francis; 2003.
- Axley J. Introduction to the design of natural ventilation systems using loop equations; Ventilation technologies in urban areas; Proceedings of the 19th AIVC Conference; Oslo, Norway. 28–30 September 1998; pp. 47–56.
- Aynsley RM, Melbourne WH, Vickery BJ. Architectural aerodynamics. London: Applied Science Publishers; 1977.
- Barker J, Stevens D, Bloomfield SF. Spread and prevention of some common viral infections in community facilities and domestic homes. Journal of Applied Microbiology. 2001;91:7–21. [PMC free article: PMC7166786] [PubMed: 11442709]
- Bassetti S, Bischoff WE, Sherertz RJ. Are SARS superspreaders cloud adults? Emerging Infectious Diseases. 2005;11(4):637–638. [PMC free article: PMC3320342] [PubMed: 15834986]
- Bloch AB, et al. Measles outbreak in a pediatric practice: airborne transmission in an office setting. Pediatrics. 1985;75(4):676–683. [PubMed: 3982900]
- Booth TF, et al. Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units. Journal of Infectious Diseases. 2005;191(9):1472–1477. [PMC free article: PMC7202477] [PubMed: 15809906]
- Calder RA, et al. Mycobacterium tuberculosis transmission in a health clinic. Bulletin of the International Union against Tuberculosis & Lung Disease. 1991;66(2–3):103–106. [PubMed: 1756290]
- CDC. Guidelines for environmental infection control in health-care facilities. Morbidity and Mortality Weekly Report. 2003;52(RR-10) [PubMed: 12836624]
- CDC. Guidelines for preventing the transmission of Mycobacterium tuberculosis in healthcare settings. Morbidity and Mortality Weekly Report. 2005;54(RR-17) [PubMed: 16382216]
- Chen PS, Li CS. Concentration profiles of airborne Mycobacterium tuberculosis in a hospital. Aerosol Science and Technology. 2008;42(3):194–200.
- Chen Q. Prediction of room air motion by Reynolds-stress models. Building and Environment. 1996;31(3):233–244.
- CIBSE. AM10 Natural ventilation in non-domestic buildings. London: the Chartered Institution of Building Services Engineers; 2005.
- Cole EC, Cook CE. Characterization of infectious aerosols in health care facilities: an aid to effective engineering controls and preventive strategies. American Journal of Infection Control. 1998;26(4):453–464. [PMC free article: PMC7132666] [PubMed: 9721404]
- Craven A, Settles GS. A computational and experimental investigation of the human thermal plume. Journal of Fluids Engineering. 2006;128(6):1251–1258.
- Dahl KM, et al. Follow-up evaluation of respiratory isolation rooms in 10 Midwestern hospitals. Infection Control and Hospital Epidemiology. 1996;17(12):816–818. [PubMed: 8985771]
- Dragan A. HVAC design approach and design criteria for health care facilities. ASHRAE Transactions: Annual Meeting. 2000:637–645.
- Duguid JF. The numbers and the sites of origin of the droplets expelled during expiratory activities. Edinburgh Medical Journal. 1945;52:335–340. [PMC free article: PMC5286249] [PubMed: 21009905]
- Edge BA, Paterson EG, Settles GS. Computational study of the wake and contaminant transport of a walking human. Journal of Fluids Engineering. 2005;127(5):967–977.
- Escombe AR, et al. Natural ventilation for the prevention of airborne contagion. PloS Medicine. 2007;4:309–317.
- Etheridge D, Sandberg M. Building ventilation — theory and measurement. Chichester, UK: John Wiley & Sons; 1996.
- Fennelly KP, Nardell EA. The relative efficacy of respirators and room ventilation in preventing occupational tuberculosis. Infection Control and Hospital Epidemiology. 1998;19(10):754–759. [PubMed: 9801283]
- Fennelly KP, et al. Cough-generated aerosols of Mycobacterium tuberculosis: a new method to study infectiousness. American Journal of Respiratory and Critical Care Medicine. 2004;169(5):604–609. [PubMed: 14656754]
- Fitzgerald D, Haas DW. Mycobacterium tuberculosis. In: Mandell GL, Bennett JE, Dolin R, editors. Principles and practice of infectious diseases. 6th ed. Philadelphia: Churchill Livingstone; 2005. pp. 2852–2886.
- Fluent. FLUENT 6.1 user's guide. Lebanon, NH: Fluent Inc.; 2003.
- Fraser VJ, et al. Evaluation of rooms with negative pressure ventilation used for respiratory isolation in seven midwestern hospitals. Infection Control and Hospital Epidemiology. 1993;14(11):623–628. [PubMed: 8132981]
- Gardner J. Centers for Disease Control: guideline for isolation precautions in hospitals. American Journal of Infection Control. 1996;24:2–52.
- Garner JS, Simmons BP. CDC guideline for isolation precautions in hospitals. Atlanta, GA: US Department of Health and Human Services; 1983. (HHS Publication No. CDC 83-8314)
- Gerberding JL. Occupational infectious diseases or infectious occupational diseases? Bridging the views on tuberculosis controls. Infection Control and Hospital Epidemiology. 1993;14:686–687. [PubMed: 8132992]
- Ghiaus C, et al. Outdoor-indoor pollutant transfer. In: Allard F, Ghiaus C, editors. Natural ventilation in the urban environment — assessment and design. London and Sterling, VA: Earthscan; 2005.
- Gustafson, et al. An outbreak of airborne nosocomial varicella. Pediatrics. 1982;70(4):550–556. [PubMed: 6289235]
- Hamburger M, Roberston OH. Expulsion of group A hemolytic streptococci in droplets and droplet nuclei by sneezing, coughing, and talking. American Journal of Medicine. 1946;4:690–701. [PubMed: 18856764]
- Hayden CS, et al. Air volume migration from negative pressure isolation rooms during entry/exit. Applied Occupational and Environmental Hygiene. 1998;13(7):518–527.
- Heiselberg P, Bjørn E. Impact of open windows on room air-flow and thermal comfort. International Journal of Ventilation. 2002;1(2):91–100.
- Hutton MD, et al. Nosocomial transmission of tuberculosis associated with a draining abscess. Journal of Infectious Diseases. 1990;161(2):286–295. [PubMed: 2105362]
- Huynh KN, et al. A new method for sampling and detection of exhaled respiratory virus aerosols. Clinical Infectious Diseases. 2008;46(1):93–95. [PubMed: 18171219]
- Ip M, et al. Air-flow and droplet spreading around oxygen masks: a simulation model for infection control research. American Journal of Infection Control. 2007;35(10):684–689. [PMC free article: PMC7115271] [PubMed: 18063134]
- ISIAQ. ISIAQ review on indoor air quality in hospitals and other health care facilities. International Society of Indoor Air Quality and Climate; 2003.
- Jennison MW. Atomizing of mouth and nose secretions into the air as revealed by high speed photograph. Aerobiology. 1942;17:106–128.
- Klein BS, Perloff WH, Maki DG. Reduction of nosocomial infection during pediatric intensive care by protective isolation. New England Journal of Medicine. 1989;320(26):1714–1721. [PubMed: 2733733]
- Levin H. Building materials and indoor air quality. Occupational Medicine: State of the Art Reviews. 1989;4:667–693. [PubMed: 2690380]
- Li F, Niu JL. Control of volatile organic compounds indoors — development of an integrated mass-transfer-based model and its application. Atmospheric Environment. 2007;41(11):2344–2354.
- Li Y, et al. An evaluation of the ventilation performance of new SARS isolation wards in nine hospitals in Hong Kong. Indoor and Built Environment. 2007;16(5):400–410.
- Liu H. Wind engineering: a handbook for structural engineers. Englewood Cliffs, NJ: Prentice Hall; 1991.
- Loudon RG, Roberts RM. Droplet expulsion from the respiratory tract. American Review of Respiratory Disease. 1967;95:435–442. [PubMed: 6018703]
- Lowbury EJL, et al. Control of hospital infection. London: Chapman and Hall; 1975.
- Lynch T. Communicable disease nursing. St. Louis: CV Mosby; 1949.
- Maki DG. Yes, Virginia, aseptic technique is very important: maximal barrier precautions during insertion reduce the risk of central venous catheter-related bacteremia. Infection Control and Hospital Epidemiology. 1994;15(4 Pt 1):227–230. [PubMed: 8207188]
- Maloney SA, et al. Efficacy of control measures in preventing nosocomial transmission of multidrug-resistant tuberculosis to patients and health care workers. Annals of Internal Medicine. 1995;122(2):90–95. [PubMed: 7993001]
- Mastorides SM, et al. The detection of airborne Mycobacterium tuberculosis using micropore membrane air sampling and polymerase chain reaction. Chest. 1999;115(1):19–25. [PubMed: 9925058]
- Mayhall CG. Hospital epidemiology and infection control. 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2004.
- Menzies D, et al. Hospital ventilation and risk for tuberculous infection in Canadian health care workers. Annals of Internal Medicine. 2000;133(10):779–789. [PubMed: 11085840]
- Mills F. Indoor air standards in hospitals. Business Briefing: Hospital Engineering and Facilities Management. 2004:43–46.
- Morawska L. Droplet fate in indoor environments, or can we prevent the spread of infection? Indoor Air. 2006;16(5):335–347. [PubMed: 16948710]
- Nardell EA, et al. Airborne infection: theoretical limits of protection achievable by building ventilation. American Review of Respiratory Diseases. 1991;144(2):302–306. [PubMed: 1907115]
- NCDC. Isolation techniques for use in hospitals. Washington DC: National Communicable Disease Center, US Government Printing Office; 1970. (PHS Publication No. 2054)
- Nicas M, Nazaroff WW, Hubbard A. Toward understanding the risk of secondary airborne infection: emission of respirable pathogens. Journal of Occupational and Environmental Hygiene. 2005;2(3):143–154. [PMC free article: PMC7196697] [PubMed: 15764538]
- Nielsen PV. PhD thesis. Denmark: Technical University of Denmark; 1974. Flow in air conditioned rooms — model experiments and numerical solutions of the flow equations.
- Niu JL. Technology options for humidity control for hotels in south-eastern China climate. HKIE Transactions. 2001;8(2):20–24.
- Papineni RS, Rosenthal FS. The size distribution of droplets in the exhaled breath of healthy human subjects. Journal of Aerosol Medicine. 1997;10(2):105–116. [PubMed: 10168531]
- Pavelchak N, et al. Identification of factors that disrupt negative air pressurization of respiratory isolation rooms. Infection Control and Hospital Epidemiology. 2000;21(3):191–195. [PubMed: 10738988]
- Pavelchak N, et al. Negative-pressure monitoring of tuberculosis isolation rooms within New York State hospitals. Infection Control and Hospital Epidemiology. 2001;22(8):518–519. [PubMed: 11700880]
- Priolo C. Design guidelines and technical solutions for natural ventilation. In: Allard F, editor. Natural ventilation in buildings — a design handbook. London: James & James; 1998. pp. 195–254.
- Qian H, et al. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems. Indoor Air. 2006;16(2):111–128. [PubMed: 16507039]
- Rice N, Streifel A, Vesley D. An evaluation of hospital special-ventilation-room pressures. Infection Control and Hospital Epidemiology. 2001;22(1):19–23. [PubMed: 11198017]
- Riley EC, Murphy G, Riley RL. Airborne spread of measles in a suburban elementary school. American Journal of Epidemiology. 1978;107(5):421–432. [PubMed: 665658]
- Riley RL, O'Grady F. Airborne infection: transmission and control. New York: The Macmillan Company; 1961.
- Riley RL, et al. Air hygiene in tuberculosis — quantitative studies of infectivity and control in a pilot ward. Cooperative Study between the Veterans Administration, the Johns-Hopkins-University School of Hygiene and Public Health, and the Maryland-Tuberculosis-Association. American Review of Tuberculosis and Pulmonary Diseases. 1957;75(3):420–431. [PubMed: 13403171]
- Riley RL, et al. Aerial dissemination of pulmonary tuberculosis. American Journal of Hygiene. 1959;70:185–196.
- Roy CJ, Milton DK. Airborne transmission of communicable infection — the elusive pathway. New England Journal of Medicine. 2004;350(17):1710–1712. [PubMed: 15102996]
- Sawyer MH, et al. Detection of Varicella-zoster virus DNA in air samples from hospital rooms. Journal of Infectious Diseases. 1994;169(1):91–94. [PubMed: 8277202]
- Siegel JD, et al. 2007 guideline for isolation precautions: preventing transmission of infectious agents in healthcare settings. Public Health Service, US Department of Health and Human Services, Centers for Disease Control and Prevention; 2007. (http://www
.cdc.gov/ncidod /dhqp/pdf/guidelines/Isolation2007 .pdf) - Stetzenbach LD, Buttner MP, Cruz P. Detection and enumeration of airborne biocontaminants. Current Opinion in Biotechnology. 2004;15(3):170–174. [PubMed: 15193322]
- Sutton PM, et al. Evaluating the control of tuberculosis among healthcare workers: adherence to CDC guidelines of three urban hospitals in California. Infection Control and Hospital Epidemiology. 1998;19(7):487–493. [PubMed: 9702570]
- Suzuki K, et al. Detection of Varicella-zoster virus DNA in throat swabs of patients with herpes zoster and on air purifier filters. Journal of Medical Virology. 2002;66(4):567–570. [PubMed: 11857538]
- Suzuki K, et al. Spread of Varicella-zoster virus DNA to the environment from Varicella patients who were treated with oral acyclovir. Pediatrics International. 2003;45(4):458–460. [PubMed: 12911484]
- Tang JW, et al. Door-opening motion can potentially lead to a transient breakdown in negative-pressure isolation conditions: the importance of vorticity and buoyancy air-flows. Journal of Hospital Infection. 2005;61(4):283–286. [PMC free article: PMC7114940] [PubMed: 16253388]
- Tang JW, et al. Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises. Journal of Hospital Infection. 2006;64(2):100–114. [PMC free article: PMC7114857] [PubMed: 16916564]
- Toth A, et al. Tuberculosis prevention and treatment. Can Nurse. 2004;100(9):27–30. [PubMed: 15623010]
- Wehrle PF, et al. An airborne outbreak of smallpox in a German hospital and its significance with respect to other recent outbreaks in Europe. Bulletin of the World Health Organization. 1970;43:669–679. [PMC free article: PMC2427800] [PubMed: 5313258]
- Wells WF. On air-borne infection. Study II. Droplets and droplet nuclei. American Journal of Hygiene. 1934;20:611–618.
- Wells WF. Airborne contagion and air hygiene. Cambridge, MA: Harvard University Press; 1955.
- Wenzel RP. Prevention and control of nosocomial infections. 4th ed. Philadelphia: Lippincott Williams & Wilkins; 2003.
- Weschler CJ, Shields HC. The influence of ventilation on reactions among indoor pollutants: modelling and experimental observations. Indoor Air. 2000;10(2):92–100. [PubMed: 11980107]
- WHO. Guidelines for the prevention of tuberculosis in health care facilities in resource-limited settings. Geneva: World Health Organization; 1999.
- WHO. Infection prevention and control of epidemic- and pandemic-prone acute respiratory diseases in health care — WHO interim guidelines. Geneva: World Health Organization; 2007. [PubMed: 24983124]
- Wilson P. Is natural ventilation a useful tool to prevent the air borne spread of TB? PLoS Medicine. 2007;4(2):e77. [PMC free article: PMC1808100] [PubMed: 17326713]
- Wong CY. Severe acute respiratory syndrome and biology, air quality, physics, and mechanical engineering. Hong Kong Medical Journal. 2003;9(4):304–305. [PubMed: 12904623]
- Wong KC, Leung KS. Transmission and prevention of occupational infections in orthopaedic surgeons. Journal of Bone and Joint Surgery America. 2004;86-A(5):1065–1076. [PubMed: 15118055]
- Xia YZ, et al. Influence of turbulence on thermal comfort at warm conditions. Indoor Air. 2000;10(4):289–296. [PubMed: 11089332]
- Xie X, et al. How far droplets can move in indoor environments — revisiting the Wells evaporation-falling curve. Indoor Air. 2007;17(3):211–225. [PubMed: 17542834]
- Zhang H, et al. Enhanced performance of air-cooled chillers using evaporative cooling. Building Services Engineering Research and Technology. 2000;21(4):213–217.