NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM1275364 Query DataSets for GSM1275364
Status Public on Dec 01, 2014
Title PXB302-67 HCV non-treat 8W
Sample type RNA
 
Source name HCV non-treat 8W
Organism Homo sapiens
Characteristics experiment model: human hepatocyte chimeric mice
inoculated with: serum samples from HCV carriers
time: Week 8
tissue: human hepatocytes from mouse liver
Treatment protocol Interferon-alpha (7,000IU/g body weight) was administered at week 8 six hours prior to sacrifice in 5 HBV-infected and 5 HCV-infected mice.
Growth protocol Mice were inoculated with serum samples from HCV or HBV carriers via the tail vein. Mice were sacrificed by diethyl ether anesthesia. Human hepatocytes from mouse livers were finely dissected and stored in liquid nitrogen after submergence in RNA later solution.
Extracted molecule total RNA
Extraction protocol RNA samples were extracted from cells using miRNesy mini kit (Qiagen).
Label Cy5
Label protocol Amino Allyl aRNA was synthesis by Amino Allyl MessageAmp II aRNA Amplification Kit (Ambion#1753). CyeDye Coupling and fragmentation were performed as the protocol supplied by TORAY Industries, Inc..
 
Hybridization protocol Hybridized for 16 h at 37 C with rotary shake (250 rpm). Hybridization buffer and washing protocol was followed by the protocol supplied by TORAY Industries, Inc..
Scan protocol 3D-Gene Scanner ((Toray Industries Inc., Tokyo, Japan) was used for scanning. Images were quantified using Extraction(Toray Industries Inc., Tokyo, Japan).
Description tissue PXB302-67 8W
HCV-infected mice were euthanized 8 weeks after infection
Data processing The raw data of each spot was normalized by substitution with a mean intensity of the background signal determined by all blank spots’ signal intensities of 95% confidence intervals. Measurements of both duplicate spots with the signal intensities greater than 2 standard deviations (SD) of the background signal intensity were considered to be valid. A relative expression level of a given miRNA was calculated by comparing the signal intensities of the averaged valid spots with their mean value throughout the microarray experiments.
 
Submission date Nov 26, 2013
Last update date Dec 01, 2014
Contact name Satoshi Kondo
Organization name Toray Industries,Inc.
Department New Projects Development Division
Street address Tebiro 6-10-1
City Kamakura
State/province Kanagawa
ZIP/Postal code 248-8555
Country Japan
 
Platform ID GPL13915
Series (2)
GSE52752 Early and late changes in gene and miRNA expression after hepatitis B or C infection in human hepatocyte chimeric mice [tissue_mRNA]
GSE52755 Early and late changes in gene and miRNA expression after hepatitis B or C infection in human hepatocyte chimeric mice

Data table header descriptions
ID_REF
VALUE Normalized signal intensity

Data table
ID_REF VALUE
H200006131 39.139142
H200009362 52.745937
H200012193 244.56782
H200006492 88.818072
H300013003 233.42326
H200006102 353.912839
AHsV10000483 39.295838
AHsV10001584 3.715368
H200017080 50.602705
AHsV10001782 51.954038
H200010349 1.810852
CHsGV10001868 1.94046
H200016643 80.224659
AHsV10000904 null
AHsV10002530 49.352817
AHsV10002962 5.904458
CHsGV10001630 2.80811
H200012441 7.103951
H300019439 9.841368
CHsGV10002911 8.584893

Total number of rows: 24460

Table truncated, full table size 528 Kbytes.




Supplementary file Size Download File type/resource
GSM1275364_QH26702.txt.gz 1.4 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap