NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM234625 Query DataSets for GSM234625
Status Public on Jan 04, 2008
Title Low Capacity Runner - Exercise Trained Number 3 - Left Ventricle
Sample type RNA
 
Source name Left Ventricle
Organism Rattus norvegicus
Characteristics Gender: Female Age: 7 months Tissue: Left Ventricle
Extracted molecule total RNA
Extraction protocol Tissue samples (20 mg) were homogenized in 100 µL TRIzol (Life Technologies, Gaithersburg, US) using a Mixer Mill MM301 at 20-25 Hz. RNA clean-up was performed using RNA Mini kit (Qiagen, Germantown, US). Total RNA was isolated and RNA clean-up was performed according to the manufacturer's instructions.
RNA integrity, purity and quantity were assessed by Bioanalyzer (Agilent Technologies, Santa Clara, US) and Nanodrop (NanoDrop Technologies, Baltimore, US). The concentration of total RNA was measured by Nanodrop with ultraviolet spectrophotometry at 260/280 nm. RNA quality was assessed by electrophoresis on Bioanalyzer chips (Agilent Technologies, Santa Clara, US).

High quality RNA was classified as a 260/280 ratio above 1.8. Only samples with a 260/280 ratio of more than 1.8 and no signs of degradation based on Bioanalyzer results were used for analysis.
Label Biotin
Label protocol Commercial method by Affymetrix
 
Hybridization protocol Commercial method by Affymetrix
Scan protocol Commercial method by Affymetrix
Description Commercial method by Affymetrix
Data processing Gene expression were analyzed on whole-genome RAE 230 2.0 chip from Affymetrix GeneChip (Affymetrix, Santa Clara, US) comprised of 31,042 probe sets, analyzing over 30,000 transcripts and variants from over 28,000 substantiated rat genes. On the Affymetrix GeneChip arrays, each gene is represented by a set of 11-20 probe pairs consisting of a perfect match (PM) and a mismatch (MM) probe. The statistical analysis is based on summary expression measures for each probe set, RMA.
The arrays also include a set of rat maintenance genes to facilitate the normalization and scaling of array experiments. These probe sets serve as a tool to normalize or scale your data prior to performing data comparison. All normalization genes show consistent levels of expression over defined sample sets.
Statistical analysis for finding differential expressed genes
For each gene (probeset), a linear regression model, including parameters representing the effect of aerobe capacity is specified. Based on the estimated effects, tests for significant differential expression are performed using T-tests. However, to improve the power of the tests, the T-tests are modified by replacing the gene-specific variance estimates by estimates found by borrowing strength from data on the remaining genes. The software package Limma implementing the method is available as part of the Bioconductor project.

To account for multiple testing, we calculate adjusted p-values controlling the False Discovery Rate (FDR). Consequently, selecting differentially expressed genes based on a threshold of 0.05 on the adjusted FDR p-values means that the expected proportion of genes falsely classified as differential expressed should be below 0.01 or 0.05. The model is fitted using the R statistical package (R Development Core Team, 2004).
RMA using the Bioconduction libraries
The summary measures are computed based on a linear statistical model for background-corrected, normalized and log-transformed PM values for each probe pair denoted the robust multiarray average (RMA) method. The PM values are normalized using the quantile normalization method, normalizing the arrays such that the empirical distribution of the expression measures is equal across arrays.
 
Submission date Oct 04, 2007
Last update date Aug 14, 2011
Contact name Anja Bye
E-mail(s) [email protected]
Organization name NTNU
Street address Olav Kyrres gt 9
City TRONDHEIM
ZIP/Postal code 7489
Country Norway
 
Platform ID GPL1355
Series (1)
GSE9445 Low and High Capacity Runners - Sedentary and Trained: Left Ventricle

Data table header descriptions
ID_REF
VALUE Low Capacity Runner - Exercise Trained Number 3 - Left Ventricle

Data table
ID_REF VALUE
1367452_at 10.7183818523762
1367453_at 10.7116492850392
1367454_at 9.56590669387225
1367455_at 11.2607713428091
1367456_at 10.9668233822982
1367457_at 8.80756170290821
1367458_at 8.16593854520291
1367459_at 11.3459681034512
1367460_at 10.4752421817665
1367461_at 8.75882791446051
1367462_at 10.9979053467985
1367463_at 11.3577611410750
1367464_at 9.26994608307461
1367465_at 9.19935978663006
1367466_at 9.8874501414667
1367467_at 11.1925744148466
1367468_at 9.42409489694858
1367469_at 12.0971206447821
1367470_at 10.0552204634788
1367471_at 9.50596935843584

Total number of rows: 31099

Table truncated, full table size 849 Kbytes.




Supplementary file Size Download File type/resource
GSM234625.CEL.gz 2.6 Mb (ftp)(http) CEL
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap