NCBI Logo
GEO Logo
   NCBI > GEO > Accession DisplayHelp Not logged in | LoginHelp
GEO help: Mouse over screen elements for information.
          Go
Sample GSM5908400 Query DataSets for GSM5908400
Status Public on Mar 31, 2022
Title pFUS 7-weeks Obese ZDF Intestine 8
Sample type SRA
 
Source name Obese ZDF
Organism Rattus norvegicus
Characteristics model: Obese ZDF
tissue: Intestine
gender: Male
treatment: pFUS 7-weeks
Treatment protocol The porta hepatis was targeted for ultrasound stimulation using a 1.1 MHz single-element focused ultrasound system comprised of a signal generator (Model 33120A, Agilent Technologies Inc., Santa Clara, CA), a RF power amplifier (Model 350L, Electronics & Innovation Ltd., Rochester, NY) and a 1.1 MHz focused single-element ultrasound transducer (Model H102, Sonic Concepts Inc., Bothell, WA). The transducer was acoustically coupled to the animal through a 6-cm tall plastic standoff cone filled with degassed water. Prior to treatments, all rats were anesthetized at 2-4% isoflurane at 1 L/min O2. The Target porta hepatis was localized using a custom ultrasound imaging device (Vivid E9; GE Healthcare). Animals either received 3 minutes of ultrasonic stimulus (1.1 MHz, 200mV per pulse, 150 burst cycles, 500 µs burst period) or Sham stimulus where no energy was applied.
Growth protocol n.a.
Extracted molecule total RNA
Extraction protocol Tissue were rapidly collected at the terminal time point and and treated with RNAlater tissue storage reagent. RNA extraction from tissues, assessment of RNA quality and RNA sequencing were performed at the Roswell Park Cancer Institute, Genomics Shared Resource, Buffalo, New York.
Sequencing RNA libraries were prepared using the TruSeq Stranded mRNA Sample Preparation Kit (Illumina, San Diego, CA) according to the manufacturer’s instructions for the RNA from all tissues except the pancreas and adipose. For these samples, TruSeq Stranded Total RNA Sample Preparation Kit was used.
 
Library strategy RNA-Seq
Library source transcriptomic
Library selection cDNA
Instrument model NextSeq 550
 
Data processing Fastq files of the paired end reads were merged into two files for each sample, one for R1 and one for R2 using Unix commands.
Base quality control was checked using Fast QC v0.10.1 from Babraham Bioinformatics.
Sequencing reads were mapped to the annotated rat genome version, Rattus norvegicus Rnor 6.0.91, using STAR_2.5.3a aligner.
Transcript abundance estimates were generated from the sorted BAM files using RSEM.
Genome_build: Rnor_6.0
Supplementary_files_format_and_content: rsem_genes_read_counts.csv : comma-delimited text file that includes the table of raw read counts for every gene and every sample
Supplementary_files_format_and_content: rsem_isoforms_read_counts.csv : comma-delimited text file that includes the table of raw read counts for every transcript and every sample
 
Submission date Feb 21, 2022
Last update date Mar 31, 2022
Contact name John Graf
Organization name GE Global Research
Street address One Research Circle
City Niskayuna
State/province New York
ZIP/Postal code 12309
Country USA
 
Platform ID GPL25029
Series (1)
GSE197097 Transcriptomic profiling of diabetic rats treated with peripherical focused ultrasound (pFUS)
Relations
BioSample SAMN26136569
SRA SRX14240043

Supplementary data files not provided
SRA Run SelectorHelp
Raw data are available in SRA
Processed data are available on Series record

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap