U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

Links from BioProject

SRX4679013: Genome Sequence of Escherichia coli O103 str. RM8385
1 ILLUMINA (Illumina MiSeq) run: 725,057 spots, 362.6M bases, 222.6Mb downloads

Design: Illumina libraries were prepared for all strains using the KAPA Low-Throughput Library Preparation Kit with Standard PCR Amplification Module (Kapa Biosystems, Wilmington, MA), following manufacturer's instructions except for the following changes: 750 ng DNA was sheared at 30 psi for 40 s and size selected to 700-770 bp following Illumina protocols. Standard desalting TruSeq LT and PCR Primers were ordered from Integrated DNA Technologies (Coralville, IA) and used at 0.375 and 0.5 M final concentrations, respectively. PCR was reduced to 3-5 cycles. Libraries were quantified using the KAPA Library Quantification Kit (Kapa), except with 10 l volume and 90-s annealing/extension PCR, then pooled and normalized to 4 nM. Pooled libraries were requantified by ddPCR on a QX200 system (Bio-Rad), using the Illumina TruSeq ddPCR Library Quantification Kit and following manufacturer's protocols, except with an extended 2-min annealing/extension time. The libraries were sequenced 2 250 bp paired end v2 on a MiSeq instrument (Illumina) at 13.5 pM, following manufacturer's protocols.
Submitted by: United States Department of Agriculture, Agricultural Research Service
Study: Escherichia coli O103 str. RM8385 genome sequencing
show Abstracthide Abstract
The rise in foodborne-related outbreaks of non O157 shiga-toxin producing E. coli (STECs) emphasizes the importance of developing improved methods to rapidly detect and characterize STECs. The major serovars of STEC associated with illness have been O26, O111, O103, O121, O45, and O145, accounting for 25-50% of human illness caused by STECs and, in some cases, severe illness comparable to illness caused by E. coli O157:H7. Sequencing of STECs from the agriculturally important region of the California central coast will address the diversity of genomic content and physiology of STECs compared to E. coli O157.
Sample: Pathogen: Bos taurus-associated sample of Escherichia coli O103
SAMN08724650 • SRS3772806 • All experiments • All runs
Library:
Name: 08385_S13_L001
Instrument: Illumina MiSeq
Strategy: WGS
Source: GENOMIC
Selection: RANDOM
Layout: PAIRED
Runs: 1 run, 725,057 spots, 362.6M bases, 222.6Mb
Run# of Spots# of BasesSizePublished
SRR7828044725,057362.6M222.6Mb2018-09-13

ID:
6338386

Supplemental Content

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...