Status |
Public on Mar 01, 2009 |
Title |
24h Average vs. Mock, 24 hrs vs. miR-302a*, 24 hrs, a |
Sample type |
RNA |
|
|
Channel 1 |
Source name |
Mouse ES cells
|
Organism |
Mus musculus |
Characteristics |
24h Average
|
Extracted molecule |
total RNA |
Extraction protocol |
Qiagen RNeasy spin columns with DNAse treatment
|
Label |
Cy3
|
Label protocol |
custom automated version of the aminoallyl MessageAmp II kit from Ambion.
|
|
|
Channel 2 |
Source name |
Mouse ES cells
|
Organism |
Mus musculus |
Characteristics |
Mock, 24 hrs vs. miR-302a*, 24 hrs, a
|
Extracted molecule |
total RNA |
Extraction protocol |
Qiagen RNeasy spin columns with DNAse treatment
|
Label |
Cy5
|
Label protocol |
custom automated version of the aminoallyl MessageAmp II kit from Ambion.
|
|
|
|
Hybridization protocol |
Microarrays are incubated at 40°C for 48 hours in a rotating carousel. Hybridizations to custom Agilent microarrays are completed as previously described (Hughes et al.Nat Biotech (2001), 19(4):342-7). Microarrays are washed to remove non-specific hybridized sample. Afterwards, microarrays are dried in an ozone-free nitrogen chamber.
|
Scan protocol |
Microarrays are scanned using the Agilent LP2 laser scanner. The scanner output is a Tiff file, which contains the quantitative hybridization data from each individual microarray. The Tiff files are then processed using Rosetta custom feature extraction software.
|
Description |
targets of miRNAs regulated by MYC in mouse ES cells
|
Data processing |
Data were processed using the Rosetta Resolver® system. Rosetta's custom feature extraction software performs error modeling before data are loaded into the Resolver system. The Resolver system performs a squeeze operation that combines replicates of the same sequence in an array while applying error weighting. The error weighting consists of adjusting for additive and multiplicative noise. A P-value is generated and propagated throughout the system. The P-value represents the probability that a gene is expressed. The Resolver system allows users to set thresholds, below which genes of a P-value are considered to be significantly expressed. The Resolver system also combines multiple arrays using a squeezing process. If multiple spots reference one sequence, summarization is performed using an error-weighted average as described in Roland Stoughton and Hongyue Dai, Statistical Combining of Cell Expression Profiles. US Patent #6,351,712, February 26, 2002.
|
|
|
Submission date |
Apr 02, 2008 |
Last update date |
Dec 22, 2008 |
Contact name |
Aimee Jackson |
Organization name |
Regulus Therapeutics
|
Street address |
1896 Rutherford Rd
|
City |
Carlsbad |
State/province |
CA |
ZIP/Postal code |
92008 |
Country |
USA |
|
|
Platform ID |
GPL3677 |
Series (1) |
GSE13127 |
Myc influences embryonic stem cell pluripotency by regulating miRNAs |
|